A Comparative Study of Standard Peripheral Blood Smear and Antigen Detection Test in Diagnosis of Malaria in a Tertiary Care Hospital in Jalandhar
Keywords:
Plasmodium falciparum, Plasmodium vivax, malaria diagnosis,, rapid diagnostic testAbstract
Background: Malaria can cause fatal complications if the diagnosis and treatment are delayed. So, quick detection and early
treatment of malaria are the best policies for the management of disease. Microscopy has been the gold standard for malaria
diagnosis for decades. Recently, many new rapid diagnostic tests (RDTs) are being widely used. We have made an attempt
to compare peripheral smear and rapid antigen detection methods for the diagnosis of malaria. Material and methods: A
total of 500 blood samples were collected from patients presenting with symptoms of malaria. Thin and thick blood smears
were prepared and stained with Leishman’s stain. Plasmodium falciparum (Pf) HRP-2 antigen and Plasmodium vivax (Pv)
specific pLDH detection was done using rapid test device for malaria diagnosis. Results: Out of the 500 blood samples
tested, only 3.4% were positive for malaria. Difference between the positivity for Plasmodium species by both methods was
0.6%. Sensitivity, specificity, positive predictive value and negative predictive values were 85%, 99.6%, 89.5% and 99.4%,
respectively with peripheral blood film (PBF) method. Conclusion: The study highlights that the RDT, for diagnosis of
malaria, is as reliable as microscopy. Microscopy is simple, economical, sensitive and specific but it is time consuming and
requires a microscope. In places where such facilities are not available, rapid, simple and easy to interpret antigen detection
test can be done.
Downloads
Published
Issue
Section
License
All open access articles published in IJCP are distributed under the terms of the CC BY-NC 4.0 license (Creative Commons Attribution-Non-Commercial 4.0 International Public License). This license permits unrestricted use, distribution, and reproduction of the articles in any medium for non-commercial purposes, provided that: The original authorship is properly and fully attributed. The IJCP is cited as the original place of publication with correct citation details. If an original work is reproduced or disseminated in part or as a derivative work, this must be clearly indicated. No articles are reproduced for commercial use without prior consent from the IJCP. All licensing requests and permissions for commercial use will be managed by the Publisher.